The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.
Features:
1. 12.1” TFT screen displays the ventilation parameters, alarm information, and oscillograms, make every operation more easily.
2. Multiple ventilation mode can meet different clinical requirements ( IPPV, A/C, SIMV, PCV, PSV, SPONT/CPAP, SIGH, MANUAL)
3. Multiple parameters monitoring interface,make every parameter clear for users to know patient condition in all respects.
4. P-T, F-T, P-V loop oscillograms and high precision oxygen concentration detection function included.
5. Humidifier can heat and wet breathing gas, makes it comfortable for patient to breathe.
6. Rapid oxygen supply,automatically offer high flow rate oxygen within two minutes
7. High temperature resistance breathing circuit is reusable and anti-pollution.
Technical Specification:
Ventilation modes: | IPPV, A/C, SIMV,PCV, PSV,SPONT/CPAP, SIGH, Manual |
Ventilator parameter ranges | |
Tidal volume(Vt) | 0 ,20mL ~ 2000 mL |
Frequence(Freq) | 1bpm ~ 100 bpm |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 40 cmH2O |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters | |
Frequence(Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration | 0 mL ~ 2500 mL 0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) |
Oxygen concentration | 15 % ~ 100 % |
Graphical display: | Oxygen concentration |
Size:Wooden case packing size:Main engine:L 560 * W 560 * H 615 mm GW.35KG, NW.17KG Air compressor: L 685 * W 690 * H 1140 ,GW.100KG, NW.65KG Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
High oxygen concentration alarm Low oxygen concentration alarm | 19%-100% 18%-99% |
High Airway pressure alarm Low Airway pressure alarm High Minute Volume alarm Low Minute Volume alarm Continuous Pressure alarm | 20cmH2O-100cmH2O 0cmH2O-20cmH2O 5L/min-99L/min 1L/min-30L/min (PEEP+1.5kPa) over 16s |
Suffocation warning | 5s-60s |
The maximum limited pressure | <12.5 kPa |
Fan error Oxygen deficit | Show on screen Show on screen |
Working conditions | |
Gas source | O2,AIR |
Pressure | 280kPa-600kPa |
Voltage | -220V±22V |
Power frequency | 50Hz±1Hz |
Input power | 900VA(with air compressor) |
Contact: Cherrie Tsai