Welcome: Wuhan Aochen ME Technology Co., Ltd
Chinese   English 
cherrie@aochenme.com 15871393781

High-end anesthesia machine for surgery S6100

1. 10.4″ TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform.

2. High precision flow meter, instantly know the fresh gas flow to your patient.

3. Integration breathing circuit design, ensure easy operating and keep tidy.

4. Multiple working modes such as volume control and pressure limit, adapt to wide range patient.

5. Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.

6. Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;

7. Real-time pressure-time, flow-time loop graphics and high precision O2 concentration detection function included.

8. Vital sign monitor and Anesthetic gas monitor are optional.

9. ETCO2 module is optional.

Technical Specification:

S6100

Specifications

Ventilation modes:

IPPV; A/C; PCV; SIMV; SIGH,MANU

Ventilator parameter ranges


Flow meter

O2(0.1-10L/min)


N2O(0.1-10L/min)


AIR(0.1-10L/min)

Rapid oxygen supply

35L/min-75L/min

Tidal volume(Vt)

0, 20 mL ~ 1500 mL

Frequence(Freq)

1bpm ~ 100 bpm

I/E

4:1~1:8

PEEP

0cmH2O ~ 30 cmH2O

Pressure triggering sensitivity(PTr)

-20 cmH2O ~ 0 cmH2O(Based on PEEP)

Flow trigger sensitivity (FTr)

0.5 L/min ~ 30 L/min

Pressure control (PC)

5 cmH2O ~ 60 cmH2O

SIGH

0(off) 1/100 ~ 5/100

Apnea Ventilation

OFF,5 s ~ 60 s

Pressure Limit

20 cmH2O ~ 100 cmH2O

Monitored Parameters


Frequence(Freq)

0 /min ~ 100 /min

Tidal volume(Vt)

0 mL ~ 2000 mL

MV

0 L/min ~ 100 L/min

Oxygen concentration

15 % ~ 100 %

Graphical display:


P-T(pressure – time)


F-T(flow – time)


P-V loop (pressure – volume loop)


Alarm and protection


The AC power failure alarm

Power failure or no connection

Internal battery backup low voltage alarm

<11.3±0.3V

No tidal volume

≤5Ml within 6s

High oxygen concentration alarm

19%-100%

Low oxygen concentration alarm

18%-99%

High Airway pressure alarm

20cmH2O-100cmH2O

Low Airway pressure alarm

0cmH2O-20cmH2O

High Minute Volume alarm

Adult(5L/min-20L/min)

Low Minute Volume alarm

Paed(1L/min-15L/min  0-10L/min)

Continuous Pressure alarm

(PEEP+1.5kPa) over 16s

Suffocation warning

5s-60s no spontaneous ventilation

The maximum limited pressure

<12.5 kPa

Fan error

Show on screen

Oxygen deficit

Show on screen

Working conditions


Gas source

O2,N2O,AIR

Pressure

280kPa-600kPa

Voltage

100-240V


INQUIRY