The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments. From high to low acuity, simple to complex cases, pediatric to geriatric patients, Superstar Medical Anesthesia Systems offer you the choices you need in ventilation, monitoring and technique. what’s more, our expertise in anesthesia delivery and ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring.
7” TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform.
High precision flow meter, instantly know the fresh gas flow to your patient.
Integration breathing circuit design, ensure easy operating and keep tidy.
Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
Vaporizer with temperature, flow compensation and self-lock function (S6100D can only equipped with one vaporizer), keep safety anytime.
Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;
Real time pressure-time, flow-time loop graphics and high precision O2 concent
Technical Specification:
Ventilation modes: | IPPV, A/C, SIMV, SIGH, MANUAL |
Ventilator parameter ranges | |
Flow meter | O2(0.1-10L/min) |
N2O(0.1-10L/min) | |
AIR(0.1-10L/min) | |
Rapid oxygen supply | 35L/min-75L/min |
Tidal volume(Vt) | 0, 20 mL ~ 1500 mL |
Frequence(Freq) | 1bpm ~ 100 bpm |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 30 cmH2O |
Pressure triggering sensitivity(PTr) | -20 cmH2O ~ 0 cmH2O(Based on PEEP) |
Flow trigger sensitivity (FTr) | 0.5 L/min ~ 30 L/min |
Pressure control (PC) | 5 cmH2O ~ 60 cmH2O |
SIGH | 0(off) 1/100 ~ 5/100 |
Apnea Ventilation | OFF,5 s ~ 60 s |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters | |
Frequence(Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2000 mL |
MV | 0 L/min ~ 100 L/min |
Oxygen concentration | 15 % ~ 100 % |
Graphical display: | |
P-T(pressure – time) | |
F-T(flow – time) | |
P-V loop (pressure – volume loop) | |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | <11.3±0.3V |
No tidal volume | ≤5Ml within 6s |
High oxygen concentration alarm | 19%-100% |
Low oxygen concentration alarm | 18%-99% |
High Airway pressure alarm | 20cmH2O-100cmH2O |
Low Airway pressure alarm | 0cmH2O-20cmH2O |
High Minute Volume alarm | Adult(5L/min-20L/min) |
Low Minute Volume alarm | Paed(1L/min-15L/min 0-10L/min) |
Continuous Pressure alarm | (PEEP+1.5kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | <12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Working conditions | |
Gas source | O2,N2O/AIR |
Pressure | 280kPa-600kPa |
Voltage | 100-240V |